View Issue Details

IDProjectCategoryView StatusLast Update
0001376CaseTalk ModelerGeneralpublic2022-01-10 20:40
ReporterBCP Software Assigned ToBCP Software  
PriorityhighSeveritymajorReproducibilityalways
Status closedResolutionfixed 
PlatformIntelOSWindowsOS Version7
Fixed in Version8.23 
Summary0001376: Select properties of an object type via an IGD generates a error
DescriptionCalling for object type properties via an IGD (refer to typecase 01.png) generates a type-cast-error (refer to typecase 02.png)

After this error, just right-clicking on an object type in an IGD, generates a generic error (refer to typecast 03.png)

Interesting: CTRL-E does not generate an error in either case.
Steps To ReproduceOpen Project.
Open IG.
Open IGD.
Right click on Object type on IGD, select properties (typecase 01.png).
Error: typecase 02.png.
Close IGD.
Open IGD.
Just right click on object type.
Error: typecase 03.png.
TagsNo tags attached.
CaseTalk Edition

Activities

Robert Geurts

Robert Geurts

2017-06-23 08:15

reporter   ~0000903

Extra note, the same as 1368: the severity of the error is due to the fact that the application becomes unstable, there are multiple generic "Access violations" and the only solution is restarting the complete CTK Modeler.

BCP Software

BCP Software

2017-06-23 08:15

administrator   ~0000904

There is a difference in menu activation: Ctrl+E activates the menu "Tasks\Edit" whereas the mentioned "Properties" item is there to adjust some graphical settings within the drawing.
The typecast indeed exists in the Graphical Properties Dialog. It is fixed in the upcoming release.
BCP Software

BCP Software

2017-06-23 08:15

administrator   ~0000905

Solved in v8.23
BCP Software

BCP Software

2022-01-10 20:40

administrator   ~0003233

Closing automatically, stayed too long in resolved state. Feel free to re-open with additional information if you think the issue is not resolved.

Issue History

Date Modified Username Field Change
2017-06-23 08:15 BCP Software New Issue
2017-06-23 08:15 BCP Software Status new => assigned
2017-06-23 08:15 BCP Software Assigned To => BCP Software
2017-06-23 08:15 BCP Software Issue generated from: 0001367
2017-06-23 08:15 BCP Software Note Added: 0000903
2017-06-23 08:15 BCP Software Note Added: 0000904
2017-06-23 08:15 BCP Software Note Added: 0000905
2017-06-23 08:16 BCP Software Project DNB => CaseTalk Modeler
2017-06-23 08:16 BCP Software Status assigned => resolved
2017-06-23 08:16 BCP Software Resolution open => fixed
2017-06-23 08:16 BCP Software Fixed in Version => 8.23
2022-01-10 20:40 BCP Software Note Added: 0003233
2022-01-10 20:40 BCP Software Status resolved => closed