Summary0004391: Model file fails to open due to reference issues
DescriptionAn older model file cannot be opened due to missing records.
TagsNo tags attached.
CaseTalk Editionunknown

Activities

Marco Wobben

Marco Wobben

2024-02-05 14:27

administrator   ~0005089

If the older model files contains schema names ending with a 0 (zero), and other schemas which end with a 1 (one), the sorting function makes a mistake and indexes are nog loaded properly. The file is still correct, you need to upgrade to a new CaseTalk or open it with an older.

Issue History

Date Modified Username Field Change
2024-02-05 14:25 Marco Wobben New Issue
2024-02-05 14:25 Marco Wobben Status new => assigned
2024-02-05 14:25 Marco Wobben Assigned To => Marco Wobben
2024-02-05 14:25 Marco Wobben Priority normal => immediate
2024-02-05 14:27 Marco Wobben Status assigned => resolved
2024-02-05 14:27 Marco Wobben Resolution open => fixed
2024-02-05 14:27 Marco Wobben Fixed in Version => 13.1.2
2024-02-05 14:27 Marco Wobben Note Added: 0005089